Apex Digital 5708009-C COMMAND SET FOR THE RS-232, AE BUS HOST PORT, Host Data, Response, RF off

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 91
Image 91
COMMAND SET FOR THE RS-232, AE BUS HOST PORT

Apex 1 to 5.5 kW Generator

Table 4-5.CSR Codes for RS-232, AE Bus Host

51Duty cycle out of range

52Minimum on/off time violated (on/off time must be ≥ 10 µs).

99

Command not implemented

COMMAND SET FOR THE RS-232, AE BUS HOST PORT

Table 4-6 lists the command set for the RS-232, AE Bus Host port.

Table 4-6.Host Port Commands for RS-232 with AE Bus

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

1

Requests RF output off; request is always

0

1

RF off

honored regardless of which interface has

 

 

 

control. (Readback command is 162.)

 

 

 

 

 

 

2

Requests RF output on; host control must

0

1

RF on

have been selected.

 

 

 

 

 

 

3

Sets the method of output regulation (forward

1 data byte

1

regulation

power (6), load (7), and ext. (8)). (Readback

8-bit value

 

select

command is 164.)

 

 

 

 

 

 

4

Specifies maximum forward power that can

2 data bytes

1

fwd pwr

be delivered; accepts a value of 0 to 8000 W

16-bit value

 

limit

(for the 8 kW option) or 0 to 10000 W (for

 

 

 

the 10 kW option). (Readback command is

 

 

 

169.)

 

 

 

 

 

 

5

Specifies maximum reflected power that can

2 data bytes

1

refl pwr

be tolerated; accepts a value of 0 to 2000 W.

16-bit value

 

limit

(Readback command is 170.)

 

 

 

 

 

 

6

Specifies the maximum external feedback

2 data bytes

1

ext

level; accepts a value from 0 to the maximum

16-bit value

 

feedback

external feedback value. (Readback

 

 

limit

command is 171.)

 

 

 

Note: This command sets the value at which

 

 

 

the setpoint is limited during external

 

 

 

regulation

 

 

 

 

 

 

5708009-C

4-45

Page 91
Image 91
Apex Digital 5708009-C COMMAND SET FOR THE RS-232, AE BUS HOST PORT, 6. Host Port Commands for RS-232 with AE Bus, RF off