Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

188

Reports the setpoints and run times for each

 

Varies; sends

report

recipe step. The number of data bytes

 

4 data bytes

recipe step

returned depends on the number of steps in

 

for each

setpoints/

the recipe. For each recipe step, 4 data bytes

 

recipe step

run times

returned, indicating:

 

 

 

• First 2 bytes = recipe step setpoint in

 

 

 

watts

 

 

 

• Second 2 bytes = recipe step run time in

 

 

 

hundredths of seconds or joules,

 

 

 

depending on the recipe mode (recipe

 

 

 

mode is reported by CMD 188)

 

 

 

 

 

 

189

Reports the number of steps in the recipe, the

 

 

report

status of the most recent recipe run, and the

 

 

recipe

recipe mode (time or joules). Returns 3 data

 

 

steps,

bytes:

 

 

status, and

• Byte 1 = number of recipe steps

 

 

mode

 

 

 

• Byte 2 = recipe status:

 

 

 

bit 0 indicates ignition (1 = ignition

 

 

 

detected; 0 = ignition not detected)

 

 

 

bits 1, 2, and 3 indicate the most

 

 

 

recently completed step number

 

 

 

bits 4–7 are reserved or unassigned

 

 

 

• Byte 3 = recipe mode (1 = time, 2 =

 

 

 

joule)

 

 

 

 

 

 

193

Requests the RF pulsing frequency in Hz (set

 

4 data bytes

read

with CMD 93).

 

32-bit value

pulsing

Note: The response contains 4 data bytes. All

 

 

frequency

 

 

represent frequency (LSB first).

 

 

 

 

 

 

 

 

 

196

Requests the duty cycle in% ON time

 

2 data bytes

read

Note: The response contains 2 data bytes

 

16-bit value

pulsing

 

 

which represent duty cycle (LSB first)

 

 

duty cycle

 

 

in percent on time.

 

 

 

 

 

 

 

 

 

198

Requests the revision level of the mainframe

 

3 data bytes

read

software. The returning packet contains three

 

3 ASCII

mainframe

ASCII characters—one letter, followed by a

 

characters

software

two-digit number. Used in conjunction with

 

 

revision

CMD 130 to obtain the version/revision of

 

 

level

the mainframe software.

 

 

 

 

 

 

4-54

5708009-C