Apex 1 to 5.5 kW Generator

RISK OF DEATH OR BODILY INJURY

Disconnect all sources of input power before working on this unit or anything connected to it.

Do not connect any power to this unit without first connecting cooling water and ensuring there are no leaks.

Note: Either cable connectors or interlock covers must be installed to allow the generator to operate.

TO CONTROL THE GENERATOR THROUGH A USER PORT

Apex User port options are identified by PIN position 8, and they are discussed individually in “Apex User Port Options” on page 4-2. Use the generator’s PIN and Table 1-1. on page 1-4 to identify the appropriate User port section of the manual for your unit.

To connect to the User port, install the appropriate I/O cable (cable requirements are identified in the individual User port sections).

TO CONTROL THE GENERATOR THROUGH A HOST PORT

Apex Host port options are identified by PIN position 6, and they are discussed individually in “Apex Host Port Options” on page 4-37. Use the generator’s PIN and Table 1-1. on page 1-4 to identify the appropriate Host port section of the manual for your unit.

To Connect to an Apex Host Port:

1.Ensure that the required User port inputs are satisfied. The required User port inputs are identified under the Satisfying Minimal Requirements section for your User port. To determine which User port you have, see the information for PIN position 8 in Table 1-1. on page 1-4.

2.Connect and secure the appropriate serial cable to the Apex unit and the host (cable requirements are identified in the individual Host port sections).

5708009-C

5-11

Page 139
Image 139