Apex Digital 5708009-C Apex Panel Illustrations, 18. LED Status Indicators Continued, Overtemp

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 126
Image 126
Table 4-18.LED Status Indicators (Continued)

Advanced Energy®

Table 4-18.LED Status Indicators (Continued)

Indicator

Description

 

 

OVERTEMP

A flashing yellow LED warns that the internal cold plate

 

temperature is approaching the shutdown limit.

 

A continuously lit LED indicates that the internal cold

 

plate temperature has exceeded the allowable limit. When

 

this condition occurs, the RF turns off and can be turned

 

back on only after the temperature drops below the

 

warning temperature limit and a RF Off command is given

 

to clear the fault. See “Troubleshooting guide” on page 6-1

 

for more information.

 

 

ALARM

This yellow LED indicates that the generator has turned off

 

RF output due to some limit or alarm condition in the

 

generator. Some of the conditions that can cause an alarm

 

are:

 

Over-temperature

 

• Exceeded internal protection limits

 

• AC PWR outside the limits

 

In the event of an alarm condition, after correcting the fault

 

condition, an RF OFF signal has to be given to reset the

 

generator since the generator has turned off RF output. See

 

“Troubleshooting guide” on page 6-1 for more

 

information.

 

 

APEX PANEL ILLUSTRATIONS

The appearance of the front and real panels of the Apex generator is highly variable due to the number of customer-selectable options available in the product line. These options mean that the presence or absence or certain connectors, the types of connectors, and the locations of certain options (on the front or the rear panel) are variable. The following illustrations show a basic Apex option, with labels for the options that you may or may not have on your Apex unit. To find information about any of these options, see “Using this Manual to Find Information for Your Generator” on page 1-1.

4-80

5708009-C

Page 126
Image 126
Apex Digital 5708009-C manual Apex Panel Illustrations, 18. LED Status Indicators Continued, Overtemp, Alarm