Table 4-11 lists the command set for the Profibus Host port.

Table 4-11.Profibus Host Port Commands

Command

Description

Number of

Number of

 

 

Transmit

Response

 

 

Data Bytes

Data Bytes

 

 

 

 

1

Requests RF output off; request is always

0

 

RF off

honored regardless of which interface has

 

 

 

control. (Readback command is 162.)

 

 

 

 

 

 

2

Requests RF output on; host control must

0

 

RF on

have been selected.

 

 

 

 

 

 

3

Sets the method of output regulation (forward

1 data byte

 

regulation

power—6, load—7, and ext—8). (Readback

8-bit value

 

select

command is 164.)

 

 

 

 

 

 

4

Specifies maximum forward power that can be

2 data bytes

 

fwd pwr

delivered; accepts a value of 0 to 8000 W (for

16-bit value

 

limit

the 8 kW option) or 0 to 10000 W (for the 10

 

 

 

kW option). (Readback command is 169.)

 

 

 

 

 

 

5

Specifies maximum reflected power that can

2 data bytes

 

refl pwr

be tolerated; accepts a value of 0 to 20% of

16-bit value

 

limit

full rated power. (Readback command is 170.)

 

 

 

 

 

 

6

Specifies the maximum external feedback

2 data bytes

 

ext feedback

level; accepts a value from 0 to the maximum

16-bit value

 

limit

external feedback value. (Readback command

 

 

 

is 171.)

 

 

 

This command sets the value at which the

 

 

 

setpoint is limited during external regulation

 

 

 

 

 

 

8

Specifies the output setpoint level for

2 data bytes

 

setpoint

whatever method of output regulation has

16-bit value

 

 

been selected. Accepts a value of 0 to 8000 W

 

 

 

(for the 8 kW option) or 0 to 10000 W (for the

 

 

 

10 kW option) when forward or load power

 

 

 

regulation is selected.

 

 

 

 

 

 