Table 4-4.RS-232, AE Bus Host Port Pin Descriptions

Apex 1 to 5.5 kW Generator

Table 4-4.RS-232, AE Bus Host Port Pin Descriptions

Signal

Name

Description

Pin

 

 

 

 

 

1

RESERVED

Reserved for future use

 

 

 

2

TXD

RS-232 transmit data

 

 

 

3

RXD

RS-232 receive data

 

 

 

4

RESERVED

Reserved for future use

 

 

 

5

COM

Data Common

 

 

 

6

RESERVED

Reserved for future use

 

 

 

7

RESERVED

Reserved for future use

 

 

 

8

RESERVED

Reserved for future use

 

 

 

9

RESERVED

Reserved for future use

 

 

 

RS-232, AE BUS HOST PORT CABLING REQUIREMENTS

The cabling requirements for the RS-232 and AE Bus requires a standard DB-9 male to female extension cable.

COMMUNICATING THROUGH THE RS-232, AE BUS HOST PORT

The communications capability of the serial AE Bus Host port is limited to the following parameters:

RS-232 protocol

Baud rate of 19.2 kbps

Apex generator unit address of 1

Odd parity

One start bit, eight data bits, one stop bit

Low-order bytes are transmitted before high-order bytes.

The time-out period for the Apex generator is factory set at 0.02 s (that is, no more than 0.02 s can elapse between bytes, or the unit will reset and begin looking for a new message packet). This value can be changed using command 40.