Apex 1 to 5.5 kW Generator

Table 4-11.Profibus Host Port Commands (Continued)

Command

Description

Number of

Number of

 

 

Transmit

Response

 

 

Data Bytes

Data Bytes

 

 

 

 

185

Requests what percentage the generator can be

0

1 data bytes

read

out of setpoint before it starts the out-of-

 

8-bit value

allowable

setpoint timer (set with CMD 16).

 

 

deviation

 

 

 

 

 

 

 

198

Requests the revision level of the mainframe

0

3 data bytes

read

software. The returning packet contains three

 

3 ASCII

mainframe

ASCII characters—one letter, followed by a

 

characters

software

two-digit number. Used in conjunction with

 

 

revision

CMD 130 to obtain the version/revision of the

 

 

level

mainframe software.

 

 

 

 

 

 

205

Requests the amount of time (in seconds) that

0

4 data bytes

read run

the generator was producing output.

 

32-bit value

time

 

 

 

 

 

 

 

206

Requests the total amount of energy (in kWh)

0

4 data bytes

read total

delivered by the generator.

 

32-bit value

energy

 

 

 