Table 4-15.Network Status LED (Continued)

LED

State

Meaning

 

 

 

Flashing green

On-line, not connected

The unit is on-line but has

 

 

no connections in its

 

 

existing state because:

 

 

• the unit has no

 

 

established

 

 

connections to other

 

 

nodes

 

 

• the unit is not allocated

 

 

to the master.

 

 

 

Flashing amber

Connection time-out,

One or more I/O

 

critical link failure

connections are in the

 

 

timed-out state.

 

 

 

Amber

Critical link failure

Communication has failed;

 

 

that is, the unit has detected

 

 

an error that has made it

 

 

incapable of communicating

 

 

on the network.

 

 

 

For information about Module Status LED indications during power-up, refer to Section 8.2.4 of the DeviceNet Specification (revision 2.0).

DEVICENET OPERATION

You may operate your Apex generator either solely through the User port or through the optional DeviceNet port.

Before operating your Apex generator through the DeviceNet port, ensure that your network is connected to the DeviceNet port and the User port. Also, ensure that you have selected an appropriate MAC ID and baud rate (see “DeviceNet Rotary Switches: Baud Rate and Addressing” on page 4-74). Finally, ensure that you have read the information about command and response messages and the DeviceNet LEDs (see “DeviceNet Control Panel LEDs” on page 4-74).

Note: To operate through the DeviceNet port, you must also have a connection through the User port’s interlock pins. For information about User port interlock pins, see the User port section that applies to your Apex unit (“Apex User Port Options” on page 4-2).

RF Power Enable can be active through the User port even though DeviceNet is in operation.