Apex 1 to 5.5 kW Generator

Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

86

Sets the pin diode 1 latch. Send 1 data byte.

1 data byte

 

Set point

• byte 1 = latch

8-bit value

 

diode 1

 

 

Note: byte 1 bits on a standard 5 pin unit:

 

 

latch

 

 

 

0: Series 3

 

 

 

1: Series 1

 

 

 

2: Shunt 1

 

 

 

3: Shunt 2

 

 

 

4: Series 2

 

 

 

5: chamber / 50 ohm

 

 

 

6: Unused

 

 

 

7: Unused

 

 

 

Note: byte 1 bits on a 2 pin unit:

 

 

 

0: Unused

 

 

 

1: Series 1

 

 

 

2: Unused

 

 

 

3: Shunt 2

 

 

 

4: Unused

 

 

 

5: Unused

 

 

 

6: Unused

 

 

 

7: Unused

 

 

 

 

 

 

93

Sets the RF pulsing frequency in Hz. Accepts

4 data bytes

1

set pulsing

a value of 150 to 50000. Read back with

32-bit value

 

frequency

command 193.

 

 

 

 

 

 

96

Sets the RF pulsing duty ON time in

2 data bytes

 

set pulsing

increments of 1%. This value can range from

 

 

duty cycle

10% to 90%. Minimum On or OFF time is >=

 

 

 

10uS.

 

 

 

 

 

 

119

Clears profibus fault and error code register

 

 

Profibus

 

 

 

Reset/

 

 

 

Explicit

 

 

 

Fault clear

 

 

 

 

 

 

 

128

Requests the generator type; returns 4 ASCII

0

4 data bytes

supply type

characters.

 

4 ASCII

 

 

 

characters

 

 

 

 

129

Requests the output capacity of the generator;

0

4 data bytes

supply size

returning packet contains 4 ASCII characters.

 

4 ASCII

 

 

 

characters

 

 

 

 

5708009-C

4-49

Page 95
Image 95