Apex Digital 5708009-C 11. Profibus Host Port Commands Continued, Description, Number of, number

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 114
Image 114
mainframe

Advanced Energy®

Table 4-11.Profibus Host Port Commands (Continued)

Command

Description

Number of

Number of

 

 

Transmit

Response

 

 

Data Bytes

Data Bytes

 

 

 

 

130

Requests the version number of the

0

5 data byte

read

mainframe software. The returning packet

 

5 ASCII

mainframe

contains 5 ASCII characters—a 5-digit

 

characters

software

number. This command is used in conjunction

 

 

version

with CMD 198 to obtain the version/revision

 

 

number

number of the mainframe software.

 

 

 

 

 

 

155

Requests control mode (set by CMD 14).

0

1 data byte

read control

Returning values: 2 = host, 4 = analog.

 

8-bit value

method

 

 

 

 

 

 

 

156

Requests the number of the active target (set

0

1 data byte

read active

by CMD 11).

 

8-bit value

target

 

 

 

 

 

 

 

157

Requests the amount of life remaining (set by

1

4 data bytes

read target

CMD 12) in the active target you specify.

 

32-bit value

life

Two decimals are implied— 100 = 1 kWh.

 

 

 

 

 

 

4-68

5708009-C

Page 114
Image 114
Apex Digital 5708009-C 11. Profibus Host Port Commands Continued, Description, Number of, Data Bytes, mainframe, number