Apex 1 to 5.5 kW Generator

.

Table 4-14.MOD Status LED

LED

State

Meaning

 

 

 

Off

No power

the unit is not receiving

 

 

power.

 

 

 

Green (steady)

Operational

the unit is operating

 

 

normally.

 

 

 

Flashing Green

Standby

the unit needs maintenance

 

 

because the configuration is

 

 

missing, incomplete, or

 

 

incorrect.

 

 

 

Amber

Unrecoverable Fault

the unit has experienced a

 

 

fault from which it cannot

 

 

recover; you may need to

 

 

replace the unit.

 

 

 

Flashing Amber/Green

Device Self-Testing

the unit is running self

 

 

diagnostics

 

 

 

Note: For information on LED flash rates, refer to section 8.2.8 of the DeviceNet Specification (revision 2.0).

Note: For information about Module Status LED indications during power-up, refer to Section 8.2.4 of the DeviceNet Specification (revision 2.0).

Devicenet Network Status LED

The NET bi-color (amber/green) LED indicates the status of the communication link. The following table shows the LED’s various states and their meanings.

Table 4-15.Network Status LED

LED

State

Meaning

 

 

 

Off

No power

The unit is not on-line

 

 

because:

 

 

• it has not completed the

 

 

Dup_MAC_ID test yet

 

 

• it is not receiving

 

 

power (check the MOD

 

 

LED).

 

 

 

Green (steady)

Link okay

The unit is on-line and

 

 

allocated to the master

 

 

 

5708009-C

4-75

Page 121
Image 121