| 1. Introduction | |
General Specifications |
|
|
|
| |||
Electrical Specifications |
|
|
|
| |||
| Item |
|
|
| Specification |
| |
| Supply Voltage |
| 5 V DC (supplied from a controller) |
| |||
| Power Consumption |
| 5.5 W |
| |||
| Ambient Temperature during Operation |
| |||||
| Relative Humidity during Operation |
|
| ||||
PROFIBUS DP Communication Specifications | |||||||
| Item |
|
|
| Specification |
| |
| Connection Method |
| Hybrid |
|
|
|
|
|
|
| (token passing procedure and |
| |||
| Baud Rates |
| 9.6 kbps, 19.2 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, |
| |||
|
|
| 1500 kbps, 3 Mbps, 6 Mbps, and 12 Mbps. |
| |||
| Transfer Distance |
| Baud Rates |
| Cable Length |
| |
|
|
| 12 Mbps |
| 100 m |
| |
|
|
| 6 Mbps |
| 100 m |
| |
|
|
| 3 Mbps |
| 100 m |
| |
|
|
| 1500 kbps |
| 200 m |
| |
|
|
| 500 kbps |
| 400 m |
| |
|
|
| 187.5 kbps |
| 1000 m |
| |
|
|
| 93.75 kbps |
| 1200 m |
| |
|
|
| 19.2 kbps |
| 1200 m |
| |
|
|
| 9.6 kbps |
| 1200 m |
| |
| Maximum Stations |
| 126 (including master unit and repeater) |
| |||
| Data Length / Frame |
| 244 bytes |
|
|
|
|
| Cable |
|
|
Fieldbus I/O Rev.6 | 7 |