4. Troubleshooting (PROFIBUS DP)
4.2.2.1 Master: Communication Error
Master Unit LED | Error |
| Description | |||
BF | ST |
| ||||
|
|
|
| |||
Light | Red | Communication |
| - Slave disconnected from the network | ||
OFF | Light | error |
| (Remote I/O communication error) | ||
|
| Blinking |
|
| - Slave not added to the network (Scan list | |
|
|
|
|
| collation error) |
|
|
|
|
|
| - Nonstandard wiring |
|
|
|
|
|
| - No or too many terminating resistors | |
|
|
|
|
| - Noise intrusion |
|
4.2.2.1.1 Master/Slave: Communication Error |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| BF | ST |
| Master LED Condition |
| Light OFF | Red Light Blinking | ||
| Absent Slave LED Condition |
| Light OFF | Green Light Blinking | ||
| (Communication error) |
| Light OFF | Red Light Blinking |
116 | Fieldbus I/O Rev.6 |