4. Troubleshooting (DeviceNet)

Process Flowchart

Check

5

 

 

 

Check the following:

 

 

 

 

- Unconnected terminating resistor

Problem exists. (Fix it.)

 

† No Problem

 

- Unconnected or loose connector/signal wire

 

 

 

 

- Cable disconnection

See 4.1.3.1 and 4.1.3.2.

 

 

 

 

 

No problem

 

 

† No Problem

 

Measure voltage of

Problem exits. (Fix it.)

 

 

communications power supply.

 

 

 

 

No problem

 

 

† No Change

 

Replace the master unit.

The problem is fixed.

 

 

 

 

 

 

No change

 

 

† No Change

 

Replace moving cable

The problem is fixed.

 

 

 

 

 

(Replace deteriorated cable).

 

 

 

 

No change

 

 

† No Change

 

Check for noise influence.

The problem is fixed.

 

 

 

 

 

 

 

See 4.1.3.3.

 

 

 

 

 

 

No change

 

 

† The trouble unit is not found.

 

 

 

Rarely

Does an error occur immediately?

 

 

 

 

 

 

 

 

Immediately

 

 

 

 

Divide the network and

The unit is found.

 

 

 

find the trouble unit.

 

 

 

 

The unit is not found.

Replace the unit.

 

 

 

 

Normal Communication?

Yes

 

 

 

 

 

 

 

No

 

 

 

„ Analyze the network with NetMeter.

 

 

 

 

„ Consult the DeviceNet manufacturer.

 

Finish

 

 

 

 

Fieldbus I/O Rev.6

87