4. Troubleshooting (DeviceNet)

4.1.3.6 EPSON RC+ Master Configuration

For details of EPSON RC+ master configuration, refer to the section 2.5 DeviceNet Board Installation.

The following section describes the procedure for verifying the scanner board condition with applicomIO Console application.

4.1.3.6.1 Verifying applicomIO Console application condition

The status bar at the bottom of the window shows the applicomIO Console application status. The status bar varies as shown below:

Character:

The address number of the scanner board is indicated with

 

characters. When the character “F” appears, the flash memory

 

on the board initialized the scanner board.

Background color:The background color indicates the scanner board status. For details, refer to the table below.

Background

Character

Status

Gray

Black

Access to scanner board was failed.

 

 

After that, the status bar will not be renewed

 

 

automatically. To renew the status bar, right-click

 

 

the status bar and select Refresh.

Magenta

Black

The scanner board was initialized with an earlier

 

 

version applicomIO Console application.

 

 

It is recommended that the scanner board be written

 

 

into the flash memory (reinitializing the scanner

 

 

board) again with the current version applicomIO

 

 

Console application.

Red

Black

The scanner board was not initialized.

 

 

Initialize the scanner board to use it.

Yellow

Black

The scanner board was partially initialized.

 

 

This status happens only during network detection

 

 

and on-line actions.

Dark green

White

Although the scanner board was initialized, it is

 

 

different than the currently opened configuration.

 

 

(Different version, etc.)

 

 

It is recommended that the scanner board be written

 

 

into the flash memory (reinitializing the scanner

 

 

board) again with the current version applicomIO

 

 

Console application.

 

 

This status happens only during network detection,

 

 

on-line actions, and diagnostic.

Green

Black

The scanner board was initialized properly and it is

 

 

no different with the currently opened

 

 

configuration.

 

 

This status happens only during network detection,

 

 

on-line actions, and diagnostics.