4. Troubleshooting (DeviceNet)

4.1.2.1 Master: Communication Error

Master Unit LED

Error

Description

MS

NS

 

 

Green

Red Light

Communication

- Slave disconnected from the network

Light ON

Blinking

error

(Remote I/O communication error)

 

 

 

- Slave not added to the network

 

 

 

(Scan list collation error)

 

 

 

- Communications power supply OFF

 

 

 

(Error detection after the communication

 

 

 

establishment)

4.1.2.1.1 Slave: Not Operating

 

MS

NS

Master LED Condition

Green Light ON

Red Light Blinking

Absent Slave LED Condition

Light OFF

Light OFF

♦ Process Flowchart

Check1

† No Problem

Is power supplied to slaves?

No

 

Yes

No

Supply power.

Is MS LED light ON? Yes

Replace the unit.

Normal communication? Yes

No

Finish

See other errors.

82