4. Troubleshooting (DeviceNet)

♦ Causes of Error

 

 

 

 

 

 

Countermeasure

 

Possible Cause

 

Examination Method

 

{ Voltage drop of

Measure voltage of

 

 

Check voltage of the power

 

communications

communications power supply at

supply.

 

power supply

the master unit.

 

 

 

 

 

→ Normal: 11V or more between

 

 

 

V+ and V-

 

 

 

 

 

 

z If the voltage is 11 to 14 V, the

 

 

 

unit is a possible cause. Fix the

 

 

 

problem on the unit.

 

Fix the problem.

 

{ Disconnected

(1)

Check

 

that

terminating

 

terminating

 

resistors are connected to both

 

 

resistors

 

ends of the network.

 

How to find the trouble

 

{ Cable

(2)

Measure

resistance

between

point:

 

disconnection

 

signal

 

wires

with

Remove the terminating

 

{ Disconnected

 

communications power supply

resistor on one end of the

 

connector

 

OFF.

 

 

 

 

network. The trouble point

 

{ Disconnected

→ Normal: 50 to 70

 

is where resistance changes

 

signal wire

z Measuring point: Connection of

from 120 .

 

 

the master

 

 

 

 

 

 

z For detail, refer to the section

 

 

 

4.1.3.1 Connection Problem.

Connect the connectors and

 

{ Loose connector

Check for the connection of

 

{ Loose signal wire

connectors and signal wires.

signal wires again.

 

 

→ The connectors and signal

 

 

 

wires should be firmly

 

 

 

 

connected.

 

 

 

 

 

 

z Checkpoint: Between the master

 

 

 

and its slaves

 

 

 

 

 

z For details, refer to the section

 

 

 

4.1.3.2 Loose Connector and

 

 

 

Signal Wire.

 

 

 

Supply power to the slaves.

 

{ All slaves power

Measure the power voltage of the

 

OFF

slaves.

 

 

 

 

 

 

 

(It should be within the range of

 

 

 

sufficient voltage for the slave

 

 

 

operation.)

 

 

 

 

Change the configuration.

 

{ Master unit

(1)

Start

applicomIO

Console

 

configuration

 

application and check that the

 

 

 

 

configuration

has

no

 

 

 

 

difference

with

the

network

 

 

 

 

condition.

 

 

 

 

 

 

(2) Check

that the configuration

 

 

 

 

data were written in flash.

 

zFor details, refer to the section 4.1.3.6 EPSON RC+ Master Configuration.

Fieldbus I/O Rev.6

95

Page 107
Image 107
Epson EM07ZS1647F manual From 120 Ω