2. Installation
2.9 EtherNet/IP Board Installation
Following two board types can be used for the fieldbus I/O option EtherNet/IP. -
2.9.1 Board Appearance
Part names and functions of the scanner board are shown in the following figure. For details of the status display LEDs, refer to the 4. Troubleshooting in this manual.
PCU-ETHIO
| |
Watchdog Port | Jumper for Board Address |
(Do not use this port.) | JP1 |
LED (2) | |
(Not in use) |
|
| |
(Not in use) | JP1 |
Status Display LED (2) | 0 |
| |
| 1 |
EtherNetI/P Connector | C0 C1 C2 |
2.9.2 Specifications
Part Number | applicom |
|
|
Modes | Master/Slave |
|
|
Baud Rates | 10, 100 Mbps |
|
|
Interface | EtherNet/IP 1 port |
|
|
Maximum Node | 127 |
|
|
Connection Type | Cyclic, Change of State |
|
|
Explicit messaging | Yes |
|
|
EDS support | Yes |
|
|
Input Data Size | 1 to 505 bytes |
|
|
Output Data Size | 1 to 509 bytes |
|
|
Automatic Detection | Yes. Devices can be detected automatically. |
|
|
54 | Fieldbus I/O Rev.6 |