4. Troubleshooting (DeviceNet)
Status Code
General Protocol
45
47
53
55
65
70
79
63
66
93
99
255
Descriptions
Initialize the applicomIO® interface before use by running the PcInitIO
Targeted applicomIO® card invalid or incorrectly initialized by the function IO_Init Synchronization problem on the line.
Additional information:
The DeviceNet master is "off line" (power supply not detected or the CAN component of the applicomIO® is "Bus Off")
Check the network wiring and Baud Rate. Response
Additional information:
The device accepted the connection but did not answer the request.
Check the device status. Connection denied. Additional information:
Connection to the DeviceNet master is in progress or refused by the device.
Connection finished. Additional information:
Duplication of MAC ID detected on the DeviceNet network.
Modify the MAC ID of the DeviceNet master. Profile incompatible.
Additional information:
The device does not match the configuration. Check the device identity and the connection sizes. Indicates that a communication error has been encountered on serial Port.
Not enough applicomIO® interface memory. Driver cannot be accessed.
Indicates that applicomIO® solution is already running.
Indicates that the local input buffer was not updated beforehand by the function IO_RefreshInput.
Fieldbus I/O Rev.6 | 109 |