Error messages
Error codes appear in the time data display when an error (usually a hardware problem) occurs. In addition, both error messages and error codes appear in the monitor video section and on the video monitor connected to the unit. When an error message appears, follow the instructions in the error message to resolve the problem.
Error code
E r r o r 5 0 - 0 1 0
Error code in time data display area
ERROR
AN ERROR HAS BEEN
DETECTED. INFORM SERVICE
OF FOLLOWING CODE:
PRESS EJECT KEY
TO EJECT DISC.
Error code
Example error in video monitor screen
To eject discs with the unit powered off
As an emergency measure, disc cartridges can be removed with the unit powered off. This operation should always be done by a trained service technician.
Specifications
General
External dimensions (w/h/d, excluding projections) 210×132×396 mm (8 3/8×5 1/4×15 5/8
inches)
396 (15 5/8)
|
| ) |
|
| 4 |
|
| / |
|
| 1 |
|
| 132 (5 |
| 210 (8 3/ ) | in mm (inches) |
| 8 | |
Mass | 6.5 kg (14 lb. 5 oz.) |
|
Power requirements |
| |
| 100 V to 240 V AC, 50/60 Hz | |
| 12 V DC |
|
Power consumption |
| |
| AC operation: 80 W |
|
| DC operation: 65 W |
|
| (Power saving mode: 55 W) | |
|
| Appendix |
Peak inrush current
(1) Power ON, current probe method:
45 A (240 V), 18 A (100 V)
(2) Hot switching inrush current, measured in accordance with European standard
Operating temperature
5ºC to 40ºC (41ºF to 104ºF) Storage temperature
25 to 90%
System
Recording/playback format
Video | MPEG HD 422: 50 Mbps |
Specifications 123