Preparations 3 Chapter
out steps 2 to 5. Settings are made in hexadecimal
You can record ID codes in user bits.
To record timecode that follows sequentially upon the last recorded timecode (Internal Regen)
You can record timecode so that it is continuous from one clip to the next on the disc.
Set TCG on page P4 TC of the function menu to INT, and PRST/RGN to TC or VITC. When this setting is in force, the unit reads the timecode of the last frame of the last recorded clip on the disc before starting to record, and internally generates timecode that follows upon the recorded timecode.
The frame count mode (for system frequency 59.94i only) is set to the same mode as the last recorded timecode on the disc
To record with the internal timecode generator synchronized to external timecode (External Regen)
Use this method to synchronize the timecode generators of a number of recorders, to record the playback timecode of external VTRs, or to record while maintaining synchronization between the source video and timecode. Use either of the following procedures according to the type of external timecode.
Synchronizing with timecode input to the TIME CODE IN connector
1 Connect the timecode output of an external device to the TIME CODE IN connector, and input a reference video signal to the REF. VIDEO INPUT connector.
2 Make the following settings on page P4 TC of the function menu.
•Set TCG to “EXT”.
•Set PRST/RGN to “TC”.
Synchronizing with embedded LTC input to the HDSDI INPUT connector
1 Connect an HDSDI signal containing embedded LTC to the HDSDI INPUT connector, and input a reference video signal to the REF. VIDEO INPUT connector.
2 Make the following settings on page P4 TC of the function menu.
•Set TCG to “SDI”.
•Set PRST/RGN to “TC”.
Executing either of these procedures starts the internal timecode generator running in synchronization with the external timecode generator.
Once the internal timecode generator is synchronized with the external timecode generator, the internal timecode generator continues to run even if the external timecode generator connection is removed.
The timecode advance mode is set automatically to Free Run. The frame count mode (for system frequency 59.94i only) is set to the same mode as the external timecode signal
To check the synchronization to the external signal
Press the STOP button to stop this unit, then press the REC button.
Check that the timecode value shown in the time data display coincides with the external timecode value.
To record external timecode directly (External Preset)
When you use this method, the internal timecode generator advances without being affected by the external timecode.
To directly record timecode input to the TIME CODE IN connector
Connect the timecode output of an external device to the TIME CODE IN connector, and make the following settings on page P4 TC of the function menu.
•Set TCG to “EXT”.
•Set PRST/RGN to “PRESET”.
36 Setting Timecode