Press the switch axially to output preview key signals from the EXT I/O connector.

See the table “Iris adjustment functions” (page 54).

Press

OPEN

CLOSE

Iris adjustment functions

 

Relative mode

Absolute mode

 

(IRIS RELATIVE button lit)

(IRIS RELATIVE button out)

IRIS lever (RCP-920)

Adjusts the iris with relative values within 1/4 of

Adjusts the iris within the variable range set by

IRIS control knob

the total range from OPEN to CLOSED.

the SENS and COARSE controls.

(RCP-921)

 

 

 

 

 

COARSE control knob

Adjusts the total range from OPEN to CLOSED

Sets the lower limit for CLOSED.

 

in relative values.

 

 

 

 

SENS control knob

Does not function.

Sets the upper limit for OPEN, referenced to the

 

 

CLOSED value set by the COARSE control.

 

 

 

Iris/master black control block (RCP-921)

 

a EXT indicator

 

d IRIS/MB ACTIVE button

f IRIS display

 

h MASTER BLACK display

c AUTO button

 

i SENS control knob

e IRIS RELATIVE button

 

 

b Spare button

 

j COARSE control knob

 

k IRIS control knob

 

l Iris gauge

 

m MASTER BLACK control knob

54 Location and Function of Parts