2Turn the right adjustment knob to change the setting, and press ENTER button.

The shutter display setting is changed.

4 Press CLEAR button.

The first screen of the RCP configuration menu reappears.

The SHUTTER display on the SHUTTER page of the paint menu will be displayed as an angle (degree units).

¯

To change the RCP number

When using the RCP-920/921 in a multi-camera network system, you must assign the unit a unique device number. When connecting the unit to a CCU directly or connecting the unit to a CNU, this configuration is not necessary.

Note

Malfunctions may occur if you assign the RCP a number that is already in use by another device in a multi-camera system connected via Ethernet. Be sure to assign a different number for each device.

1 Move the cursor to SETTING in the RCP configuration menu, and press ENTER button.

The settings and adjustment screens appear.

2 Use the v and V buttons to move through the settings and adjustment screens, and display the <RCP No. SET> page.

3 Change the RCP number setting.

1Press ENTER button to enable configuration. The cursor appears as “?” and the setting flashes.

2Turn the right adjustment knob to change the setting, and press ENTER button.

The RCP number setting is changed.

4 Press CLEAR button.

The first screen of the RCP configuration menu reappears.

To change the output destination for previews (RCP-920)

When you press the IRIS control lever/preview switch on the RCP-920, preview key signals are output. You can enable or disable the output settings for destinations individually.

The output destinations you can configure are as follows.

EXT I/O connector on the RCP unit (Factory setting: ON)

External output connector on the CCU (Factory setting: OFF)

S-BUS system via the CNU (Factory setting: OFF)

1 Move the cursor to SETTING in the RCP configuration menu, and press ENTER button.

The settings and adjustment screens appear.

2 Use the v and V buttons to move through the settings and adjustment screens, and display the <PREVIEW> page.

3 Turn the right adjustment knob to move the cursor to the preview output destination you want to configure.

To configure the EXT I/O connector on the RCP unit, move the cursor to CONTACT.

4 Change the preview output setting.

1Press ENTER button to enable configuration. The cursor appears as “?” and the setting flashes.

Initial Settings 67