2Press ENTER button to enable configuration. The cursor appears as “?.”

3Press ENTER button again to save the settings.

4 Press CLEAR button.

The first screen of the RCP configuration menu reappears.

To configure Ethernet connection settings

The RCP-920/921 supports connections to camera network systems via the Ethernet connector. Perform the following steps to configure Ethernet connection settings.

Notes

To apply the configurations, you must restart the unit.

This setting can only be configured in Engineer mode.

1 Move the cursor to SETTING in the RCP configuration menu, and press ENTER button.

The settings and adjustment screens appear.

2 Use the v and V buttons to move through the settings

and adjustment screens, and display the <TCP/IP SETTING> page.

Note

The LCD can only display up to four setting items at one time. If a page has more than four items, turn the right adjustment knob to scroll the page.

¯

3 Configure the TCP/IP settings.

The items you can configure are as follows.

IP ADDRESS: Set the IP address to assign the RCP.

SUBNET MASK: Set the subnet mask of your network environment.

DEFAULT GATEWAY: If necessary, set the default gateway of your network environment.

Set the IP address of this unit.

1Turn the right adjustment knob to move the cursor to IP ADDRESS.

2Press ENTER button to enable configuration. The cursor appears as “?” and the first section of the IP address flashes.

3Turn the right adjustment knob to change the setting, and press ENTER button.

The second section of the IP address flashes. Set this section of the IP address as you did above.

¯

4Enter the entire IP address, and press ENTER button.

The IP address of this unit is set.

¯

4 Set the subnet mask and default gateway.

Configure the subnet mask and (if necessary) the default gateway as you did the IP address.

¯

5 Save the TCP/IP settings.

1Turn the right adjustment knob to move the cursor to SET in the upper right of the screen.

2Press ENTER to enable configuration. The cursor appears as “?.”

3Press ENTER button again to save the settings.

6 Press CLEAR button.

The first screen of the RCP configuration menu reappears.

To configure Ethernet interface settings

Notes

To apply the configurations, you must restart the unit.

This setting can only be configured in Engineer mode.

1 Move the cursor to SETTING in the RCP configuration menu, and press ENTER button.

The settings and adjustment screens appear.

74 Initial Settings