2 Electrical Specifications

This section lists the electrical specifications, the absolute maximum ratings, the recommended operating conditions and operating characteristics for the TCM4300 Advanced RF Cellular Telephone Interface Circuit.

2.1Absolute Maximum Ratings Over Operating Free-Air Temperature Range (unless otherwise noted)²

Supply voltage range:

 

 

 

DVDD (see Notes 1 and 2)

VSS ±0.3 V to AVDD +0.3

V

AVDD (see Notes 2 and 3)

VSS ±0.3 V to DVDD +0.3

V

Input voltage range, VI: Digital signals

VSS ±0.3 V to DVDD +0.3

V

Analog signals

VSS ±0.3 V to AVDD +0.3

V

Output voltage range, VO: Digital signals

. . . . . . . . . . .

. VSS to DVDD

Analog signals

. . . . . . . . . . .

. VSS to AVDD

Continuous total power dissipation

See Dissipation Rating Table

Operating free-air temperature range, TA

. . . . . . . . . . .

±40°C to 85°C

Storage temperature range, Tstg

. . . . . . . . . .

±65°C to 150°C

Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds

. . . . . . . . 260°C

²Stresses beyond those listed under ªabsolute maximum ratingsº may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under ªrecommended operating conditionsº is not implied. Exposure to absolute-maximum-rated conditions for

extended periods may affect device reliability. NOTES: 1. Voltage values are with respect DVSS.

2.Maximum supplied voltage should not exceed 6 V.

3.Voltage values are with respect to AVSS.

2.2Dissipation Rating Table

PACKAGE

TA 25°C

DERATING FACTOR

TA = 85°C

POWER RATING

ABOVE TA = 25°C

POWER RATING

 

PZ

1530 mW

15.25 mW/°C

615 mW