2–1
2 Electrical Specifications
This section lists the electrical specifications, the absolute maximum ratings, the recommended operating
conditions and operating characteristics for the TCM4300 Advanced RF Cellular Telephone Interface
Circuit.

2.1 Absolute Maximum Ratings Over Operating Free-Air Temperature Range

(unless otherwise noted)
Supply voltage range:
DVDD (see Notes 1 and 2) VSS –0.3 V to AVDD +0.3 V. . . . . . . . . . . . . . . . . . . . . .
AVDD (see Notes 2 and 3) VSS –0.3 V to DVDD +0.3 V. . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, VI: Digital signals VSS –0.3 V to DVDD +0.3 V. . . . . . . . . . . . . . . . .
Analog signals VSS –0.3 V to AVDD +0.3 V. . . . . . . . . . . . . . . .
Output voltage range, VO: Digital signals VSS to DVDD
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Analog signals VSS to AVDD
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA –40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, Tstg –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These
are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated
under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for
extended periods may affect device reliability.
NOTES: 1. Voltage values are with respect DVSS.
2. Maximum supplied voltage should not exceed 6 V.
3. Voltage values are with respect to AVSS.

2.2 Dissipation Rating Table

PACKAGE TA 25°C
POWER RATING DERATING FACTOR
ABOVE TA = 25°CTA = 85°C
POWER RATING
PZ 1530 mW 15.25 mW/°C615 mW