3.2TCM4300 to Microcontroller Interface Timing Requirements (Mitsubishi Read Cycle) (see Figure 3±2 and Note 2)

 

PARAMETER

ALTERNATE

MIN

MAX

UNIT

 

SYMBOL

 

 

 

 

 

 

 

 

 

 

 

tsu(R/W)

Setup time, read/write MCRW stable before falling edge of

TRW(SU)

0

 

ns

strobe MCDS

 

 

 

 

 

 

 

 

 

 

 

 

th(R/W)

Hold time, read/write MCRW stable after rising edge of

TRW(HO)

10

 

ns

strobe MCDS

 

 

 

 

 

 

 

 

 

 

 

 

tsu(RA)

Setup time, read address MCS stable before falling edge of

TRA(SU)

0

 

ns

strobe MCDS

 

 

 

 

 

 

 

 

 

 

 

 

th(RA)

Hold time, read address MCA stable after rising edge of

TRA(HO)

10

 

ns

strobe MCDS

 

 

 

 

 

 

 

 

 

 

 

 

ten(RD)

Enable time, read data on falling edge of strobe MCDS to

TRD(EN)

10

 

ns

TCM4300 driving data bus MCD

 

 

 

 

 

 

 

 

 

 

 

 

tv(R)

Read data valid time on falling edge of strobe MCDS to

TRD(DV)

 

50

ns

valid data MCD

 

 

 

 

 

 

 

 

 

 

 

 

tinv

Data MCD invalid after rising edge of strobe MCDS

TRD(INV)

 

10

ns

tdis(RD)

Disable time, read data. TCM4300 releases MCD data bus

TRD(DIS)

 

28

ns

after rising edge of strobe MCDS

 

 

 

 

 

 

 

 

 

 

 

 

th(CS)

Hold time, chip select MCCSH and MCCSL stable before

TCS(HO)

0

 

ns

rising edge of strobe MCDS

 

 

 

 

 

 

 

 

 

 

 

 

tsu(CS)

Setup time, chip select MCCSH and MCCSL stable before

TCS(SU)

0

 

ns

falling edge of strobe MCDS

 

 

 

 

 

 

 

 

 

 

 

NOTE 2: Timings are based upon Mitsubishi 37732S4 (16 MHz) and Mitsubishi 3772S4L (8 MHz).

 

 

MCDS

 

 

 

 

90%

90%

 

 

 

 

 

 

 

 

10%

10%

 

 

 

(see Note A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MCRW

tsu(R / W) 90%

tsu(RA)

th(R / W)

90%

th(RA)

MCA4±MCA0

MCD7±MCD0

MCCSH

MCCSL

tv(R)

tdis(RD)

ten(RD)

tinv

90%

90%

tsu(CS)

th(CS)

10%

10%

NOTE A: Chip selection is defined as both MCCS and MCDS active.

Figure 3±2. Microcontroller Interface Timing Requirements

(Mitsubishi Configuration Read Cycle, MTS [1:0] = 10)

3±2

Page 25
Image 25