Texas Instruments TMS370 manual Secondary Configuration WindowÐthe Show Ranges Window

Models: TMS370

1 99
Download 99 pages 51.5 Kb
Page 41
Image 41

Secondary Configuration WindowÐthe Show Ranges Window

2.6Secondary Configuration WindowÐthe Show Ranges Window

A small subwindow appears when you select the show ranges function key, , from the device area of the configuration window. Figure 2±3 illustrates what the show ranges window looks like.

Figure 2±3. The Show Ranges Window

 

CONFIG:

ChooseDevice

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valid address ranges for 2732/TMS2732A

 

 

 

 

 

 

 

START

SIZE

TYPE

Vcc

Vpp

Pdt

CtrlReg

FmlyCode

BlkErase

Pbits

 

 

00000h

1000h

EPROM

5

21

10

ooh

40h

NO

O's only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27128 TMS27C128

27256 TMS27C256

2732 TMS2732A

2764 TMS2764 TMS27C64

7742 TMS7742

TMS370 16K_PE 256_DEE 4K_PE

512_DEE

C010

C050

The show ranges window does not neccesarily default to show the ranges of the chosen device. Instead, it shows the ranges of the device that the cursor is next to in the device table. You can scroll through the device table and notice the parameters changing in accordance with each new device the cursor is next to.

Table 2±3. Show Ranges Parameter Summary

Parameter

Description

 

 

Start

Valid start address for programming.

 

 

Size

Size of the valid program area.

 

 

Type

The type of memory in this range (EEPROM or EPROM).

 

 

VCC

Valid Vcc values are 0, 5, or 6 volts.

VPP

Valid Vpp values are 0, 5, 12, 12.5 or 21 volts.

pdt

Program pulse duration time.

 

 

ctrlReg

The control register.

 

 

FmlyCode

The hexadecimal family code of the device.

 

 

Blk-Erase

The block erase toggle.

 

 

Pbits ²

The program algorithm.

²The program algorithms are discussed in detail in subsection 2.6.1.