Toshiba 4511, e-STUDIO3511 manual 278, Return the saddle staple to its original position

Models: 3511 e-STUDIO3511 4511

1 313
Download 313 pages 2.5 Kb
Page 280
Image 280

7.REMOVING JAMMED STAPLES (OPTIONAL) (Cont.)

8 Return the saddle staple to its original position.

-Pull the handle of the saddle stitch holder (1) toward you and turn it (2) 90º in the direction of the arrow.

9 Return the saddle stitch unit to its original position.

10Makeset. sure that A3, A4-R or B4 paper is

-If any of the above paper sizes is not set, test stapling cannot be performed.

11 Close the front cover of the finisher. Then test stapling is automatically performed on a blank sheet.

- This is performed to avoid empty stitching.

If there is a test stapling failure and “Check staple cartridge” remains, repeat the above procedure from step 1 to 11.

(2)

(1)

12

278

12.WHEN THE GRAPHIC SYMBOLS BLINK ON THE TOUCH PANEL

 

Page 280
Image 280
Toshiba 4511, e-STUDIO3511 manual 278, Return the saddle staple to its original position