APPENDIX 4 SYSTEM MODE EO1-33029
A4.4 Printer Parameter Fine Adjustment
A4-12
A4.4 Printer Parameter
Fine Adjustment
(Cont.)
Threshold Manual Fine Adjustment (Black Mark/Feed Gap
Sensor)
With this parameter you can fine adjust the Threshold of the Black Mark
and Feed Gap Sensors. When “<3>ADJUST SET” appears, press the
[PAUSE] key 9 times to enter the Threshold Manual Fine Adjustment
(Black Mark Sensor) menu.
To change the screen to the Threshold Manual Fine Adjustment (Feed
Gap Sensor), press the [PAUSE] key again.
[FEED] key: Pressing the [FEED] key one time causes a –0.1V change,
up to 0.0V.
[RESTART]
key: Pressing the [RESTART] key one time causes a
+0.1V change, up to +4.0V.
After completing the fine adjustment, press the [PAUSE] key.
NOTE:
This is useful to fine adjust the
threshold when the media issue
is improper even after the
sensor threshold setting is
p
erformed. (See Section 6.5
Threshold Setting) If the
p
roblem cannot be resolved,
p
lease contact your nearest
TOSHIBA TEC service
representative.
7+5(6+2/'7!9
[RESTART]
[FEED]
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'5!9
7+5(6+2/'7!9
7+5(6+2/'7!9
7+5(6+2/'7!9
7+5(6+2/'7!9
7+5(6+2/'7!9
Black Mark Sensor Feed Gap Sensor
7+5(6+2/'5!9 Black Mark Sensor
Feed Gap Sensor