4. SYSTEM START-UP PROCEDURE

EO3-11106

4. SYSTEM START-UP PROCEDURE

PC Transmission Information Setting

Data transmission information setting with a PC connection is performed here.

CONDITION

Any time outside a sale

 

 

OPERATION

Mode Lock: BLIND

 

 

68 [X]

 

 

1 [ST]

 

POL Watch Timer [#]

 

 

 

 

 

 

 

 

 

 

Max. 2 digits: 0 to 99

 

 

 

 

 

(Standard: 20 sec.)

 

 

 

 

 

 

 

2 [ST] Response Watch Timer [#]

Max. 2 digits: 0 to 99 (Standard: 20 sec.)

3 [ST] Transmission Delay Timer [#]

Max. 2 digits: 0 to 99

(1 = 20 ms)

(Standard: 3 = 60 ms)

4 [ST] Transmission Delay Timer 2 [#]

2 digits: 15 to 99

(1 = 20 ms)

(Standard: 25 = 500 ms)

[AT/TL]

NOTE: When performing the key operation of 68 [X] [AT/TL], a receipt containing the currently programmed values is issued.

Example) To set the following values;

 

POL Watch Timer:

30 (sec)

Response Watch Timer:

20 (sec)

Transmission Delay Timer:

4 (80 ms)

Transmission Delay Timer 2: 25 (500 ms)

Key Operation: Mode Lock: BLIND, enter 68, depress [X]. 1 [ST] 30 [#] POL Watch Timer

2 [ST] 20 [#] Response Watch Timer

3 [ST] 4 [#] Transmission Delay Timer

4 [ST] 25 [#] Transmission Delay Timer 2 [AT/TL] To complete this setting