Toshiba MA-600 Special Rounding Process Setting, 2-digit type, Round TBL 2 Digits is selected

Models: MA-600

1 191
Download 191 pages 60.21 Kb
Page 183
Image 183
Post-rounded value
00
50
100

6. TERMINAL FILE PROGRAMMING

EO3-11106

6.40 Special Rounding Process Setting, 2-digit type

6.40Special Rounding Process Setting, 2-digit type

For Special Rounding and Denmark rounding, the pre-rounded value of the two least effective digit and the post- rounded value are set here. This operation is effective when the option “Special Rounding ACTIVE” and “2 digits subject to Special Rounding” are selected (System Option Address No. 33, Bit No. 3 SET & Bit No. 4 SET).

CONDITION

Any time outside a sale

OPERATION

Mode Lock: SET

 

1)Menu Tree

2)Operation Flowchart

Main Menu

Depress [↓] five times then [Enter].

or

Depress [6].

Depress [↓] six times then [Enter].

or

Depress [7].

*

 

Maximum value of the range of the digit

 

subject to round (2 digits)

 

 

 

 

+

 

 

Post-rounded value (2 digits)

 

 

 

 

 

 

 

 

 

 

[Enter]

 

 

 

 

 

 

 

 

 

 

[End]

 

 

 

 

 

 

 

 

ECR is being outside a sale and in SET mode.

6 OTHER” is selected.

7 ROUND TBL 2 DIGITS” is selected.

Maximum value of the range of the digit subject to round: 00 to 99

Post-rounded value: 00 to 99

This setting is ended. A long receipt is issued and the display returns to Main Menu screen.

*: Repeat for the next break entries (max. 10 breaks).

NOTES:

1.When the “Post-rounded Value” is to be 100 (i.e. the final break point), the break entry is automatically set (refer to the example below). Therefore, it does not need to be entered. Entering a value larger 99 for the Post-rounded value will not cause an error. However, the rounding process will occur only on the two least effective digits in sales entries.

2.A maximum of 10 breaks can be programmed.

3.Values for Sweden rounding are set after performing a RAM Clear.

4.Example of Sweden rounding

For the Sweden rounding, the amount total is rounded as shown below.

Pre-rounded value of the two least effective digits

0 to 24

25 to 74

75 to 99

6-163