7. OPERATION DESCRIPTIONS

7-1. FAN ONLY Operation

(MODE of the remote control : FAN ONLY)

(1)During this mode, the relay RY01 is always turned off so that only the indoor fan is operated. RY02 is always turnd on. FAN-ONLY display is lit.

1)When the FAN is set to AUTO, the indoor fan motor operates as shown in Fig 7-1-1.

2)When the FAN is set to LOW, MED, or HIGH, the indoor fan motor operates with a constant in volume as listed in Table 7-1-1.

temp.

28

 

 

 

Room

27

HIGH

 

26

MED

 

 

LOW(+)

 

25

 

 

 

24

LOW

 

LOW

 

 

 

 

 

Fig. 7-1-1 Auto setting of air volume

Table 7-1-1 Manual setting of FAN SPEED

Indication of

HIGH Air volume

FAN SPEED

(m3/h)

 

 

LOW

430

 

 

MED

510

 

 

HIGH

650

 

 

(2)Once the setting is made, the operation mode is memorized in the microcomputer so that the same operation can be effected thereafter simply by

pushing the START/STOP button.

7-2. COOL Operation

(MODE of the remote control : COOL)

(1)Compressor, outdoor fan and operation display are controlled as shown in Fig. 7-2-1.

temp.)

 

ON

 

 

 

 

 

Set–

+1

 

 

 

 

 

 

 

 

 

 

temp.

 

OFF

ON

ON

 

 

 

(Room

 

 

 

 

 

 

 

Set

 

0

 

 

 

 

 

 

 

temp.

 

Compressor Outdoor fan (RY01)

Common relay (RY02)

OPERATION display

 

 

 

 

 

 

 

 

 

Fig. 7-2-1

(2)Relays RY01 and RY02 are turned on to energize the outdoor unit, and a cool operation is carried out.

1)When the FAN is set to AUTO, the indoor fan motor operates as shown in Fig 7-2-2.

2)When the FAN is set to LOW, MED, or HIGH, the indoor fan motor operates with a constant in volume as listed in Table 7-1-1.

 

 

 

 

FAN

 

temp.)

 

 

 

 

 

 

AUTO

Manual

 

 

 

 

Set–

+4

 

HIGH

 

 

MED

 

 

 

 

 

 

temp.

+3

 

LOW(+)

to the set

 

 

 

 

 

According

(Room

+2

 

 

position

 

 

LOW

+1

 

 

 

 

 

 

 

 

 

 

 

Set

 

0

 

LOW

 

 

 

(continuous)

 

 

 

temp.

 

 

 

 

 

RY01

 

 

 

 

 

 

 

 

OFF

 

Fig. 7-2-2

(3)Once the setting is made, the operation mode is memorized in the microcomputer so that the same operation can be effected thereafter simply by pushing the START/STOP button.

– 12 –

Page 12
Image 12
Toshiba RAS-10SKX, RAS-10SAX, RAS-10SK-E, RAS-10SA-E Operation Descriptions, FAN only Operation, Cool Operation, M3/h