9-3. Troubleshooting Flowcharts
9-3-1. Power can not be Turned on (No Operation at All)
<Preliminary checks>
(1)Is the supply voltage normal?
(2)Is the connection to the AC output OK.?
Shut off the power supply from AC outlet once and turn it on after 5 seconds.
NO Does the OPERATION lamp flash?
YES
Operation |
Check Items |
Main cause |
Countermeasure |
Symptom |
Does the power turn | NO | Does the transmission | NO | |
on by pushing the | indicator of remote | |||
|
| |||
[START/STOP] button |
| control flash normally and |
| |
of the remote control? |
| transmit certainly? |
|
|
|
| YES | YES |
|
|
| (No problem) |
|
| Does the fuse | YES | Parts (R21, R109, SG01, |
|
|
| C15, C01, DB01, C02, |
| |
| (F01) blow? |
|
| |
|
| IC01, T01) are defective. |
| |
|
|
|
| |
| NO |
|
|
|
| Does the thermal | YES | Wrong wiring of |
|
| fuse blow? |
| AC cord or connecting |
|
| (Under PF. Terminal) |
| cable is defective. |
|
| NO |
|
|
|
NO | Is the indication voltage |
|
|
|
| (DC12V or 5V) of main |
|
|
|
| PC board correct? |
|
|
|
| YES |
|
|
|
|
|
|
| PC board |
|
|
|
| is defective. |
Is the voltage | NO |
| Refer to the paragraph |
|
|
|
| ||
across C02 measured |
|
|
|
|
| ||||
|
|
|
| ||||||
DC310V~340V? |
|
| before power PC board block. |
|
|
| |||
| YES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Shut off the power |
|
|
|
| |
Is the secondary |
|
| Is the secondary |
|
| SW transformer | |||
voltage of SW trans- | NO |
| supply once, and turn | voltage of SW | NO |
| |||
|
| (T01) or IC (IC01) | |||||||
former (T01) measured |
|
| it on again after dis- |
| transformer measured |
|
| for power supply | |
|
|
|
|
| |||||
DC35V, DC12V, |
|
| connecting the motor | DC35V, DC12V, |
|
| |||
|
|
|
| is defective. | |||||
and DC7V ? |
|
| connector CN10*. | and DC7V? |
|
| |||
|
|
|
|
| |||||
| YES |
| YES |
|
|
| |||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
Remote control is defective.
Replace the remote control.
Replace the thermal fuse set. Check connection.
Replace the main PC board.
Replace the main PC board.
Motor is defective.
*Be sure to disconnect the motor connector CN10 after shut off the power supply, or it will be a cause of damage of the motor.