<How to connect the connecting cable>

<How to connect the connecting cable>

Wiring of the connecting cable can be carried out without removing of the front panel.

(1)Remove the front panel.

Fully open the front panel. Disengage the support arm located in the upper center while pushing its handle leftwards, and then remove the front panel toward you.

(2)Remove the terminal cover and cord clamp.

(3)Insert the connecting cable (according to local codes) into pipe hole on the wall.

(4)Take out the connecting cable through the cable slot on the rear panel so that it is exploded by about 15 cm long in the front side.

(5)Insert the connecting cable fully into the terminal block and secure it by screw tightly.

(6)Tightening torque:1.2 N•m (0.12 kgf•m)

(7)Secure the connecting cable with the cord clamp.

(8)Fix the terminal cover and front panel on the indoor unit.

CAUTION

Be sure to refer the wiring system diagram labeled inside the front panel.

Check local electrical codes and also any specific wiring instructions or limitation.

 

Terminal block

 

 

Cord

 

Connecting

Terminal clamp

1 2

cover

 

cable

Screw

Earth

 

 

 

 

line

 

Screw

 

 

Connecting cable

 

Screw

 

Fig. 8-4-9

<Stripping length of connecting cable>

 

 

50mm

Earth line

10mm

 

 

 

 

 

2

1

10mm

40mm

For a three conductor cable

NOTE :

Use stranded wire only.

Wire type:More than H05 RN-F

Fig. 8-4-10

<How to install the front cabinet on the indoor unit>

Install the front cabinet through the opposite order of "How to remove the front cabinet".

When the panel is removed and mounted again, take the following actions:

After fastening the two screws, one each at the left and right of the air outlet, be sure to push the upper center 1 right end 2 , left end 3 and the lower center 4 of the air outlet, and confirm that no gap is left between the front cabinet and the rear plate.

If cooling (dry) operation is made without pushing the air outlet, dew can be deposited on the front cabinet surface. In addition a gap between the front cabinet and the rear plate will become wider, spoiling the appearance.

Push Push Push

3

1

2

4

Push