8-4. Indoor Unit

tInstallation place

A place which provides the spaces around the indoor unit as shown in the diagram in section 8-2.

A place where there is no obstacle near the air inlet and outlet.

A place which allows an easy installation of the piping to the outdoor unit.

A place which allows the front panel to be opened.

CAUTION

Direct sunlight to the indoor unit wireless receiver should be avoided.

The microprocessor in the indoor unit should not be too close to r-f noise sources. (For details, see the owner’s manual.)

<Remote control>

A place where there are no obstacles such as a curtain that may block the signal from the remote control.

Do not install the remote control in a place exposed to direct sunlight or close to a heating source, such as a stove.

Keep the remote control at least 1 m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference.)

The location of the remote control should be determined as shown below.

8-4-1. Cutting a Hole and Mounting Installation Plate

<Cutting a hole>

When installing the refrigerant pipes from the rear

The center of the piping slot is the above arrow.

The center of the pipe

hole is the above arrow. Pipe hole

80mm

65mm

40.5 mm

 

Fig. 8-4-2

(1)After determining the pipe hole position with the mounting plate (80 mm ), drill the pipe hole (ø65

mm) at a slight downward slant to the outdoor side.

NOTE :

When drilling the wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately.

<Mounting the installation plate>

For installation of the indoor unit, use the paper pattern on the back.

Anchor bolt hole

unit

 

(Top view)

 

 

 

 

 

 

 

65.5mm

 

 

 

5m

 

 

 

 

 

Indoor

 

5m

 

 

 

 

 

 

7m

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

65.5mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45˚

 

*7m

 

 

 

 

 

view)

 

 

 

45˚

Pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

75˚

 

 

 

 

hole

 

 

 

1

(Side

 

 

 

 

 

 

 

 

Pipe hole

 

 

Reception

 

 

 

 

 

 

 

 

 

 

 

 

Installation

Reception

Remote

 

Remote

 

Thread

 

 

range

 

 

 

8

Mounting

plate

 

 

 

 

 

range

control

 

 

 

control

Indoor unit

Weight

 

screw

 

 

 

*:Axial distance

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 8-4-1

 

 

 

 

Fig. 8-4-3

 

 

– 22 –

Page 22
Image 22
Toshiba RAS-10SK-E Installation place, Cutting a Hole and Mounting Installation Plate, Remote control, Cutting a hole