Table 9-4-2 Approximate value of the sensor (thermistor) resistance (TA, TC)

(= kΩ)

Temperature

0°C

10°C

20°C

25°C

30°C

Sensor

 

 

 

 

 

 

 

 

 

 

 

Themo Sensor

35.8

20.7

12.6

10.0

7.92

 

 

 

 

 

 

9-4-3. How to Reduce the Operation Time of the Anti-Restart Timer

Wireless remote control

Attach the diode (1S1555 or equivalent) to the rivet inside the unit through holes on the rear of the wireless remote control unit.

Push the START/STOP button to start operation with the diode attached.

Timer short diode

Fig. 9-4-1

– 47 –

Page 47
Image 47
Toshiba RAS-10SA-E, RAS-10SKX, RAS-10SAX, RAS-10SK-E How to Reduce the Operation Time of the Anti-Restart Timer, Sensor