10-3. Outdoor Unit (RAS-10SA-E, RAS-10SAX)
No. | Part name |
| Procedure | Remarks |
|
|
| ||
• Common | 1) | Stop the operation of | ||
| procedure |
| the power cord from the AC supply. |
|
|
| 2) | Remove |
|
|
|
| (1- ST1T ø4 x 10 ) |
|
|
| 3) Remove the cord clamp (2- ST2T ø4 x 12 | ) and | |
|
|
| remove the connecting cable. |
|
4)Remove the front cabinet. (7- ST1T ø4 x 10 with nylon washer)
•Pull the front lower portion toward you, and remove it pulling out upward.
‚ Capacitor for | 1) Remove the fixing screw securing the capacitor | Refer to [Electrical parts list and | |
compressor |
| band. | location] in page 55. |
|
| (1- ST2T ø4 x 8 ) |
|
| 2) | Remove the cable connected to the terminal. |
|
|
|
| |
ƒ Capacitor for fan | 1) Remove the fixing screw. | Same as above. | |
motor |
| (1- ST2T ø4 x 8 ) |
|
| 2) | Remove the cable connected to the terminal. |
|
|
|
| |
„ Overload relay | 1) Perform the process • above. |
| |
| 2) Remove terminal cover of compressor. |
| |
| 3) | Remove OL holder and pull OL relay up. |
|
| 4) | Remove Fustons of leads. |
|
– 51 –