8-4-5. Indoor Unit Installation

(1)Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks.

(2)Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate.

(3)While pressing the indoor unit onto the wall by the lower part, hook it up on the installation plate by the lower part. Pull the indoor unit toward you by the lower part to confirm that it is firmly hooked up on the installation plate.

(1)

Hook here

1 Installation plate

(2)

Push

Hook

 

Fig. 8-4-15

For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up by the specified parts.

8-4-6. Drainage

(1) Run the drain hose sloping downwards.

NOTE :

Hole should be made at a slight downward slant to the outdoor side.

Do not rise the drain hose.

Do not form the drain hose

 

into the wared shape.

50mm or more

Do not put the

Do not put the drain

drain hose end

hose end in the

into water.

drainage ditch.

Fig. 8-4-17

(2)Put water in the drain pan and make sure that the water is drained outdoors.

(3)When connecting extension drain hose, insulate the connecting part of extension drain hose with

5 shield pipe.

5 Shield pipe

Drain hose Inside the room

 

 

 

Extension drain hose

 

 

Fig. 8-4-18

Push Push

Fig. 8-4-16

CAUTION

Arrange the drain pipe for proper drainage from the unit.

Improper drainage can result in damage to property.

This air conditioner has the structure designed to drain water collected from dew, which forms on the back of the indoor unit, to the drain pan.

Therefore, do not store the power cord and other parts at a height above the drain guide.

Wall

Drain guide

Space for pipes

Fig. 8-4-19

– 27 –