10. PART REPLACEMENT

 

 

 

10. PART REPLACEMENT

10-1. Indoor Unit (RAS-10SK-E, RAS-10SKX)

No.

Part name

 

Procedure

Remarks

Front panel

1) After stopping the operation of the air conditioner, be

 

 

 

sure to turn off the circuit breaker or disconnect the

 

 

 

power plug from the AC wall socket.

 

 

2)

Open the screw caps and remove the two screws

 

 

 

fixing the front panel.

 

 

 

3)

Close the screw caps as they were.

 

 

4)

Open the horizontal louver right below by your

 

 

 

finger.

 

 

 

5)

Open the lower side of front panel until it touches

 

 

 

the horizontal louver, and remove it from the indoor

 

 

 

unit by turning it.

 

 

 

 

<To assemble the front panel>

 

 

 

1)

Fix the two screws to secure the front panel.

 

 

2)

Close the screw caps as they were.

 

 

3)

Press four places where are the center, right end,

 

 

 

left end and lower portions of

the air outlet.

 

 

4)

Check the gap between the front panel and the main

 

 

 

unit.

 

 

 

 

If cooling or drying operation is performed without

 

 

 

pressing the center of the air outlet, the surface of

 

 

 

the front panel may be covered with frost and have

 

 

 

a waterdrop.

 

Electrical part

1) Perform the process above.

 

 

assembly

2) Remove the screw securing the shield metal plate.

 

 

3)

Remove the electrical part cover by pressing the nail

 

 

 

located on upper portion of the electrical part cover.

 

 

4)

Remove the drain guide.

 

 

 

5)

Remove the screw securing to the end plate of the

 

 

 

heat exchanger.

 

 

 

6)

Remove the connector (5p) for the fan motor and

 

 

 

the connector (6p) for the louver motor from the

 

 

 

microcomputer assembly.

 

 

 

7)

After unhooking the electrical part base by pressing

 

 

 

the fixing nail located on its lower portion, draw the

 

 

 

electrical part base out toward you to remove it from

 

 

 

the main unit.

 

 

 

8)

Pull the TC sensor out from the holder of the heat

 

 

 

exchanger.

 

 

 

9)

Dress the connecting cable securely as shown in the

 

 

 

right illustration.

 

 

 

 

(Improper dressing will cause water leakage.)

ƒ Drain-pan

1) Perform the process above.

 

 

assembly

2) Remove the drain-pan by pressing the four hooks

 

 

 

downwards.

 

 

 

 

(Keep it with the drain hose.)

 

– 48 –

Page 48
Image 48
Toshiba RAS-10SAX, RAS-10SA-E service manual Part Replacement, Indoor Unit RAS-10SK-E, RAS-10SKX