9-1-3. Misleading but Good Operations (Program Controlled Operation)
The microcomputer performs the operations listed in Table
|
| Table |
|
|
|
No. | Operation of | Description |
|
|
|
1 | When the power plug or the power cord | The OPERATION lamp flashes, indicating that power is turned |
| of the indoor unit is inserted, the | on. If this happens, push the START/STOP button once to cause |
| OPERATION lamp on the setting | the lamp to stop flashing. A power outage also causes the lamp |
| indication part flashes. | to flash. |
|
|
|
2 | Fan speed remains unchanged in the dry | Fan speed is automatically controlled in the dry mode. |
| mode. |
|
|
|
|
3 | Room temperature is in the range under | The compressor will not stop while the compressor on hold timer |
| which the compressor is turned off, but | |
| the compressor will not stop. |
|
|
|
|
4 | The compressor will not switch on or off | In the dry mode, the compressor goes on and off at regular |
| even when the thermo control is operated | intervals, independent of the thermo control. |
| in the dry operation. |
|
|
|
|
5 | Compressor does not work though room | Compressor does not work while the compressor restart delay |
| temperature is in the range of turning the | |
| compressor on. | on, as the time is still active. |
|
|
|
6 | During automatic operation, the | After selection of the cooling and dry operation, the operation |
| operation mode changes. | mode is selected again when the compressor off mode continues |
|
| for 15 min. according to the room temperature. And after selection |
|
| of the dry operation, the condition of the room temperature which |
|
| is Room temp. ³Set temp.+1 and which is Room temp.<Set |
|
| |
|
| again. |
|
|
|
7 | When the power is turned on, the | When the auto restart controlling is selected, the operation is |
| operation starts automatically. | performed automatically in the previous operation mode after |
|
| the power supply has been turned on. |
|
|
|