<When the installation plate is directly mounted on the wall>
(1) | Securely fit the installation plate onto the wall by |
| screwing it in the upper and lower parts to hook |
| up the indoor unit. |
(2) | Install the installation plate horizontally in the wall. |
8-4-2. Electrical Work
(1)The supply voltage must be the same as the rated voltage of the air conditioner.
(2)Prepare the power source for exclusive use with the air conditioner.
(3) To mount the installation plate on a concrete wall |
with anchor bolts, utilize the anchor bolt holes as |
shown in the above figure. |
CAUTION
When installing the installation plate with mounting screw, do not use the anchor bolt hole. Otherwise
|
| Maximum | |
Model | Power source | running | |
|
| current | |
|
|
| |
RAS- |
|
| |
50Hz |
| ||
| |||
*220/230/240V~ | 7.5 A | ||
RAS- | |||
| |||
10SKX/ |
| ||
|
| ||
10SAX |
|
|
Plug socket
&fuse rating
16 A
Wiring
1mm2
or
more
the unit may fall down and result in personal injury and property damage.
Installation plate
(Keep horizontal direction)
Anchor bolt
Projection 15mm
or less
5mm dia, hole
3 Clip anchor
8 Mounting screw ø4 x 25
Fig.
CAUTION
Failure to firmly install the unit may result in personal injury and property damage if the unit falls.
•In case of block, brick, concrete or similar type walls, make 5 mm dia, holes in the wall.
•Insert 3 clip anchors for appropriate 8 mounting screws.
NOTE :
•Install the installation plate using 4 to 6 pieces of mounting screw securing four corners with screws.
* No adjustment is necessary.
CAUTION
•Use power specified in above table.
•This appliance can be connected to the mains in either of the following two ways.
(1)Connecting the power cord to the main power supply provided with a circuit breaker or switch with a contact of 3 mm or more.
In this case, an approved circuit breaker or switch must be used.
(2)Attaching a plug to the power cord and pluging it in to the wall outlet.
In this case, an approved power cord and plug must be used.
NOTE :
•Perform wiring works so as to allow a generous wiring capacity.
– 23 –