9-3-5. Only Outdoor Fan does not Operate

Shut off the power supply from AC outlet once and turn it on after 5 seconds.

NO

Does the OPERATION lamp flash?

 

YES

 

Does the power turn on by

NO

pushing the [START/STOP] button

 

 

of the remote control?

 

 

YES

 

 

 

 

 

NO

Is the voltage across the indoor terminal

( 1 - 2 ) 220/230/240 VAC?

 

 

YES

 

 

 

 

 

NO

Is cable connection between indoor

and outdoor units correct?

 

 

YES

 

 

 

Is the voltage across the outdoor terminal

NO

( 1 - 2 ) 220/230/240 VAC?

 

 

YES

 

 

 

 

 

NO

Are all the cords for outdoor

fan motor normal?

 

 

YES

 

 

 

 

 

NO

Is the outdoor fan motor winding normal?

(Check the winding resistance)

 

 

YES

 

 

 

 

 

NO

 

 

Is the capacitor for compressor normal?

YES

Outdoor fan motor is defective.

See "Power can not be turned on".

See "Power can not be turned on".

Relays (RY01, RY02)

or IC31 or IC30 is failure.

Correct cabling between indoor and outdoor units.

Cables between indoor and outdoor units are defective.

Correct the wire or

replace the defective cords.

Outdoor fan motor is defective.

Capacitor for outdoor fan motor is defective.

Replace the PC board.

– 41 –