5-12. Drive System Control Process

In the drive system control process, the control signal is supplied to each kind of drive system process ICs shown in the the table below.

Table 5-12-1 shows each kind of the drive system IC

control.

Table 5-12-1 Each kind of the drive system IC control

Part No.

Type name

Process

Q701

M62399FP

Process relative to R drive

(Custom: $90)

 

 

Q702

M62399FP

Process relative to G drive

(Custom: $92)

 

 

Q703

M62399FP

Process relative to B drive

(Custom: $94)

 

 

Q704

M62399FP

Process relative to VCOM, NR

(Custom: $96)

 

 

Q705

M62399FP

Process relative to NR, Bias

(Custom: $98)

 

 

 

 

 

5-13. Various Display Modes

In this system, various LED display patterns are provided in relation to the display modes shown in Table 5-8-1. Operation processes from the status of AC cord plugged to that of power on and power off will be given below.

(1)Data of the non-volatile memory are checked when the AC cord is plugged, and all the LED are turned on in red in the initial use. In second or later use, all the LEDs are turned on in green and the unit enters the standby status.

(2)In the standby status, only the ON/STANDBY LED is turned on in orange, and the main power is off and the lamp power is also off.

(3)When the power is on by pressing the ON/ STANDBY key, the unit enters a normal status in passing through following processes.

1)The main power is on, and ON/STANDBY LED turns on in green.

2)The fan power is on, and the fan starts to rotate.

3)The lamp power is on, and LAMP LED blinks in green for about 3s.

4)With the lamp turned on, LAMP LED turns on in green and the unit enters the normal status.

(4)If the lamp does not turn on, ON/STANDBY LED turns on in orange, and the LAMP LED blinks in green for about 1 min. and then the unit returns to the standby status.

(5)In the normal status, ON/STANDBY LED and the LAMP LED are turned on in green, and the main power and the lamp power are turned on.

(6)When the power is turned off by pressing the ON/ STANDBY key, the unit enters the standby status in passing through following processes.

1)When the lamp power is turned off, ON/ STANDBY LED turns on in orange.

2)The LAMP LED blinks in green for about 1 min. For this period the lamp can not be turned on again by the ON/STANDBY key.

3)When blinking of the LAMP LED stops, only the ON/STANDBY LED turns on in orange. After this, the lamp can be turned on again by the ON/STANDBY key.

(7)Moreover, the fan works for about 2 min. to lower temperature of the unit. When the main power turns off, the fan also stops and returns to the standby status.

(8)If an error occurs due to some causes, the ON/ STANDBY LED turns on in red, and the error information is kept in the display status of the LAMP and TEMP LEDs. When the error is detected, the unit enters the standby status after cooling down process for about 2 min. In this case, if the error status continues, the error display is also kept and any key entry is not accepted.

5-7

Page 18
Image 18
Toshiba TLP510U, TLP511E Drive System Control Process, Various Display Modes, Each kind of the drive system IC control