TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)

(1)List item number

(2)Type of alarm list exalarm … Alarm In motion …. Motion Detection

(3)List recoding date/time (ASCII time)

When a list is to be output or when a list is being output, an error may occur and the list output may be stopped halfway. In this case, a status to notify the error is output after the last list.

A) case 1

B) case 2

20 OK\r\n

20 OK\r\n

\r\n

\r\n

alarmlist-1\r\n

\r\n

alarmlist-2\r\n

60 FailAction\r\n

\r\n

 

60 FailAction\r\n

 

* In both cases of success and failure, the format is not the HTML format.

2) When at type=RemoveAll/RemoveSpan

Code

Status

20

OK

31InvalidEntry

32InvalidValue

Code

Status

60

FailAction

15.1.4Example

1)http://10.1.0.1/api/wblistalarm.cgi?type=Show

2)http://10.1.0.1/api/wblistalarm.cgi?type=RemoveAll

3)http://10.1.0.1/api/wblistalarm.cgi?type=RemoveSpan&StartDT=20050112000000&EndDT=20050124235959

15.1.5Notes

1)The relation between StartDT and EndDT at type= RemoveSpan should be (StartDT <= EndDT) and both should be of the yyymmddHHMMSS format.

2)At type=RemoveAll and type=RemoveSpan, the corresponding list is immediately deleted without confirmation.

3)When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.

4)This API does not check type=<value> and any argument other than StartDT=<value> and EndDT=<value> at type=RemoveSpan. Accordingly, if there are illegal arguments other than these, they are ignored.

©TOSHIBA Corp.