TOSHIBA Network Camera - IK-WB15A -

SDK (Ver 1.00.SC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

From the last page.

 

 

 

 

 

 

 

 

 

Item

 

Type

Entry name

Entry value

Std.val

Unit

 

Bottom limit

type=BottomLimitSetting

Mode

1:OFF 2:ON

1

-

 

Bottom limit position

 

 

Degree

0 - 1200

0

-

 

Log output control of cgi common to all types

 

OpeLog

No/Yes [default: Yes] (omissible)

-

-

2.1.3Output

Code

Status

20

OK

30InvalidType

31InvalidEntry

Code

Status

32InvalidValue

33InvalidOperand

34NoEntryData

Code

Status

92

CriticalError

2.1.4Example

1)http://10.1.0.1/api/wbsetptbasic.cgi?type=Default

2)http://10.1.0.1/api/wbsetptbasic.cgi?type=PTCondition&ScanSpeed=2&PowerUp=4&FreezeActivity=2

3)http://10.1.0.1/api/wbsetptbasic.cgi?type=AssociationToAlarm&Mode=2&PTByMotion=2&PresetNumber=33&Resume=1

4)http://10.1.0.1/api/wbsetptbasic.cgi?type=LeftLimitSetting&Mode=2&Degree=175

5)http://10.1.0.1/api/wbsetptbasic.cgi?type=RightLimitSetting&Mode=1

6)http://10.1.0.1/api/wbsetptbasic.cgi?type=TopLimitSetting&Mode=2&Degree=175

7)http://10.1.0.1/api/wbsetptbasic.cgi?type=BottomLimitSetting&Mode=1

2.1.5Notes

1)If only type=Set is entered and then <entry>=<value> is not entered, no setting is performed. (type=Default is an exception.)

2)Multiple type=<value> cannot be enumerated simultaneously. This API must be started for each type.

3)For only entered items, setting is performed. For the other items, their existing values are held.

4)When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.

5)Setting values of “Degree” is defined in Appendix.C.

©TOSHIBA Corp.

31

Page 36
Image 36
Toshiba Toshiba manual Type Entry name Entry value Std.val Unit