TOSHIBA Network Camera -
1) Termination status limited to ‘wblist’ type cgi
Terminate code | Meaning | Termination status | Details |
60 | Server Error | 60 FailAction\r\n | List acquisition failed. |
2) Termination status limited to ‘wbstorage’ type cgi
Terminate code | Meaning |
| Termination status | Details |
21 | Notify | 21 Inserted\r\n | The storage is inserted. | |
22 | Notify | 22 | Mounted\r\n | The storage is mounted. (Available status) |
71 | Notify | 71 | NotInserted\r\n | The storage is not inserted. |
72 | Notify | 72 | NotMounted\r\n | The storage is not mounted. (Inserted) |
73 | Storage Error | 73 | FailedToMount\r\n | Mounting the storage failed. |
74 | Storage Error | 74 | FailedToFormat\r\n | Storage formatting failed. |
3) Termination status limited to wbsetcamrecord.cgi/wbsetcamftprecord.cgi
Terminate code | Meaning |
| Termination status | Details |
50 | Client Warning | 50 | OKbutExtAlarmOFF\r\n | Though the registration related to the Alarm In was executed, the |
|
|
|
| Alarm In function is set to “OFF”. |
51 | Client Warning | 51 | OKbutMotionOFF\r\n | Though the registration related to motion detection was executed, |
|
|
|
| the Motion Detecting function is set to “OFF”. |
52 | Client Warning | 52 | OKbutExtControlOFF\r\n | Though the registration related to the Ext. Control In was executed, |
|
|
|
| the Ext. Control In function is set to “OFF”. |
Input parameter and record control to log >
The API checks whether the input parameter (Input) has an appropriate format. For a request that does not meet the specified format, one of codes 30 to 35 will be notified.
Each API can specify an option by parameter as to whether the execution result is to be recorded in the log. This function can be specified as the entry ‘OpeLog’ and can be specified at any position that is behind the ‘type’ attribute.
Namely, the following two indicates all the same setting operation:
http://10.1.0.1/wbsetcambasic.cgi?type=Set&OpeLog=No&Resolution=3… (1)
http://10.1.0.1/wbsetcambasic.cgi?type=Set&Resolution=3&OpeLog=No
©TOSHIBA Corp.
10