TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)
16.2Execute Storage Mount/Unmount
wbstoragemount.cgi
16.2.1Syntax
1)http://<camip>/api/wbstoragemount.cgi?type=<value>
16.2.2Input
Item |
| Type | Entry name |
Execute mount | type=Mount |
| - |
Execute unmount | type=Unmount |
| - |
Log output control of cgi common to all types |
| OpeLog |
Value
-
-
No/Yes [default: Yes] (omissible)
16.2.3 Output
Code | Status |
20 | OK |
30InvalidType
73FailedToMount
16.2.4Example
1)http://10.1.0.1/api/wbstoragemount.cgi?type=Mount
2)http://10.1.0.1/api/wbstoragemount.cgi?type=Unmount
16.2.5Notes
1)When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.
2)This API does not check any argument other than OpeLog=No/Yes and type=Mount/Unmount. Accordingly, if there are illegal arguments other than these, they are ignored.
©TOSHIBA Corp.