Toshiba Toshiba manual Recording Cycle Type=bySchedule Interval

Models: Toshiba

1 149
Download 149 pages 56.33 Kb
Page 28
Image 28

 

TOSHIBA Network Camera - IK-WB15A -

SDK (Ver 1.00.SC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

From the last page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

Type

Entry name

 

Entry value

Std.val

Unit

 

 

Recording Cycle

 

 

(type=bySchedule)

Interval

-33/-66/-100/-200/-333/-500/1/2/3/5/

1

second

 

 

 

 

 

 

 

10/30/60/120/180

 

 

 

 

 

 

 

 

 

 

# -33:1/30

-66:1/15

-100:1/10

 

 

 

 

 

 

 

 

 

-200:1/5 -333:1/3 -500:1/2

 

 

 

 

Record file name

 

 

 

FileName

 

 

any (max.16 bytes)

 

-

 

 

Server path

1st FTP server

 

 

Server1Path

 

 

any (max.128 bytes)

 

-

 

 

 

2nd FTP server

 

 

Server2Path

 

 

any (max.128 bytes)

 

-

 

 

Pre-Recording

 

 

type=byAlarm

NumberOfPrePicture

0/3/5/10

 

 

10

frames

 

 

Post-Recording

 

 

 

NumberOfPostPicture

0/3/5/10/20

 

 

10

frames

 

 

Recording Cycle

 

 

 

Interval

-33/-66/-100/-200/-333/-500/1/2/3/5/

1

second

 

 

 

 

 

 

 

10/30/60/120/180

 

 

 

 

 

 

 

 

 

 

# -33:1/30

-66:1/15

-100:1/10

 

 

 

 

 

 

 

 

 

-200:1/5

-333:1/3

-500:1/2

 

 

 

 

Recording file

Alarm In

 

 

AiFileName

 

 

any (max.16 bytes)

 

-

 

 

name

Motion Detection

 

 

MdFileName

 

 

any (max.16 bytes)

 

-

 

 

Server path

1st FTP server

 

 

Server1Path

 

 

any (max.128 bytes)

 

-

 

 

 

2nd FTP server

 

 

Server2Path

 

 

any (max.128 bytes)

 

-

 

 

Recording Cycle

 

 

type=byExtControlIn

Interval

-33/-66/-100/-200/-333/-500/1/2/3/5/

1

second

 

 

 

 

 

 

 

10/30/60/120/180

 

 

 

 

 

 

 

 

 

 

# -33:1/30

-66:1/15

-100:1/10

 

 

 

 

 

 

 

 

 

-200:1/5

-333:1/3

-500:1/2

 

 

 

 

Record file name

 

 

 

FileName

 

 

any (max.16 bytes)

 

-

 

 

Server path

1st FTP server

 

 

Server1Path

 

 

any (max.128 bytes)

 

-

 

 

 

2nd FTP server

 

 

Server2Path

 

 

any (max.128 bytes)

 

-

 

 

Backup mode

 

 

type=Accumulation

Mode

1:OFF 2:ON

 

1

-

 

 

Accumulation Cycle

 

 

Interval

1/2/5/10/15/30/60/120/300/600/900/

60

second

 

 

 

 

 

 

 

1800/3600

 

 

 

 

 

 

Overwrite

 

 

 

OverWriting

1:OFF 2:ON

 

 

1

-

 

 

Log output control of cgi common to all types

 

OpeLog

No/Yes [default: Yes] (omissible)

-

-

©TOSHIBA Corp.

23

Page 28
Image 28
Toshiba Toshiba manual Recording Cycle Type=bySchedule Interval