TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)

6.2Clear Logs

wbsetlogclear.cgi

6.2.1Syntax

1)http://<camip>/api/wbsetlogclear.cgi?type=Set

6.2.2Input

 

Item

 

Type

Entry name

Entry value

Std.val

Unit

Clear logs

 

type=Set

 

-

-

-

-

Log output control of cgi common to all types

 

OpeLog

No/Yes [default: Yes] (omissible)

-

-

6.2.3Output

Code

Status

 

Code

Status

20

OK

 

32

InvalidValue

30

InvalidType

 

33

InvalidOperand

31

InvalidEntry

 

34

NoEntryData

6.2.4Example

1)http://10.1.0.1/api/wbsetlogclear.cgi?type=Set

Code

Status

40FailToSave

92CriticalError

6.2.5Notes

1)After this API is started, the log is deleted immediately without confirmation.

2)Accordingly, take extreme care to handle this API.

3)When saving results in a failure, the message FailToSave is output. This status does not match with the purpose of the function. Please disregard this message.

4)When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.