TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)
6.2Clear Logs
wbsetlogclear.cgi
6.2.1Syntax
1)http://<camip>/api/wbsetlogclear.cgi?type=Set
6.2.2Input
| Item |
| Type | Entry name | Entry value | Std.val | Unit |
Clear logs |
| type=Set |
| - | - | - | - |
Log output control of cgi common to all types |
| OpeLog | No/Yes [default: Yes] (omissible) | - | - |
6.2.3Output
Code | Status |
| Code | Status |
20 | OK |
| 32 | InvalidValue |
30 | InvalidType |
| 33 | InvalidOperand |
31 | InvalidEntry |
| 34 | NoEntryData |
6.2.4Example
1)http://10.1.0.1/api/wbsetlogclear.cgi?type=Set
Code | Status |
40FailToSave
92CriticalError
6.2.5Notes
1)After this API is started, the log is deleted immediately without confirmation.
2)Accordingly, take extreme care to handle this API.
3)When saving results in a failure, the message FailToSave is output. This status does not match with the purpose of the function. Please disregard this message.
4)When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.
©TOSHIBA Corp.
59