Toshiba Toshiba manual Wbsetnwkbandwidth.cgi

Models: Toshiba

1 149
Download 149 pages 56.33 Kb
Page 47
Image 47

TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)

3.2Bandwidth Control Settings

wbsetnwkbandwidth.cgi

3.2.1Syntax

1)http://<camip>/api/wbsetnwkbandwidth.cgi?type=Default

2)http://<camip>/api/wbsetnwkbandwidth.cgi?type=Set[&Mode=<value>][&Numeric=<value>][&BandWidth=<value>]

3.2.2Input

Item

Type

Entry name

 

Entry value

 

Std.val

Unit

Reset to Default

type=Default

-

-

 

 

-

-

Function

type=Set

Mode

1:OFF

2:ON

 

1

-

Band numeric

 

Numeric

 

 

any (0<n<=102400)

100

-

Band unit

 

BandWidth

1:Kbit/S

2:Mbit/S

 

2

-

Log output control of cgi common to all types

OpeLog

No/Yes [default: Yes] (omissible)

 

-

-

3.2.3Output

Code

Status

20

OK

30InvalidType

31InvalidEntry

Code

Status

32InvalidValue

33InvalidOperand

34NoEntryData

Code

Status

92

CriticalError

3.2.4Example

1)http://10.1.0.1/api/wbsetnwkbandwidth.cgi?type=Default

2)http://10.1.0.1/api/wbsetnwkbandwidth.cgi?type=Set&Mode=2&Numeric=256&BandWidth=1

3.2.5Notes

1)If only type=<value> is entered and then <entry>=<value> is not entered, no setting is performed. (type=Default is an exception.)

2)Multiple type=<value> cannot be enumerated simultaneously. This API must be started for each type.

3)For only entered items, setting is performed. For the other items, their existing values are held.

4)When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.

©TOSHIBA Corp.

42

Page 47
Image 47